{"product_id":"msa-altair-io-dock-for-altair-io-6-10253973","title":"MSA ALTAIR io Dock for ALTAIR io 6 - 10253973","description":"\u003cdiv style=\"border-radius: 20px; overflow: hidden; box-shadow: 0 14px 34px rgba(0,0,0,.08); border: 1px solid #f3f3f3; background: #ffffff; color: #444444;\"\u003e\n\u003c!-- HERO --\u003e \u003cdiv style=\"padding: 18px 26px 12px 26px; border-bottom: 2px solid #07fc0f;\"\u003e \u003ch2 style=\"text-align: center; margin: 0; color: #444444; font-size: 28px; letter-spacing: .2px;\"\u003e\u003cspan style=\"font-size: x-large;\"\u003eMSA ALTAIR io Dock for ALTAIR io 6 - 10253973\u003c\/span\u003e\u003c\/h2\u003e \u003c\/div\u003e \u003c!-- Hero \/ Key Value --\u003e \u003cdiv style=\"padding: 18px 26px 18px 26px;\"\u003e \u003cdiv style=\"background: #f3f3f3; border: 1px solid #ffffff; border-radius: 14px; padding: 16px;\"\u003e \u003cdiv style=\"font-size: 18px; font-weight: bold; margin-bottom: 6px; color: #444444;\"\u003eKeep your ALTAIR io 6 fleet compliant with less manual work\u003c\/div\u003e \u003cdiv style=\"color: #888888;\"\u003eThe ALTAIR io6 Dock enables calibration and bump testing that helps improve compliance and safety...\u003c\/div\u003e \u003cdiv style=\"margin-top: 12px; display: flex; flex-wrap: wrap; gap: 10px; width: 100%; justify-content: center;\"\u003e \u003cdiv style=\"flex: 1; min-width: 200px; background: #ffffff; border: 1px solid #f3f3f3; border-radius: 12px; padding: 14px; text-align: center;\"\u003e \u003cdiv style=\"font-weight: bold; color: #444444;\"\u003ePart Number\u003c\/div\u003e \u003cdiv style=\"color: #888888;\"\u003e10253973\u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1; min-width: 200px; background: #ffffff; border: 1px solid #f3f3f3; border-radius: 12px; padding: 14px; text-align: center;\"\u003e \u003cdiv style=\"font-weight: bold; color: #444444;\"\u003eDesigned for\u003c\/div\u003e \u003cdiv style=\"color: #888888;\"\u003eALTAIR io 6\u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1; min-width: 200px; background: #ffffff; border: 1px solid #f3f3f3; border-radius: 12px; padding: 14px; text-align: center;\"\u003e \u003cdiv style=\"font-weight: bold; color: #444444;\"\u003eReporting\u003c\/div\u003e \u003cdiv style=\"color: #888888;\"\u003eMSA Grid (cloud)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Highlights --\u003e \u003cdiv style=\"padding: 0 26px 18px 26px;\"\u003e \u003cdiv style=\"background: #ffffff; border-top: 1px solid #07fc0f; border-radius: 14px; padding: 16px; border-left: 1px solid #f3f3f3; border-right: 1px solid #f3f3f3; border-bottom: 1px solid #f3f3f3;\"\u003e \u003cdiv style=\"font-size: 18px; font-weight: bold; margin: 0 0 10px 0; color: #444444;\"\u003eHighlights\u003c\/div\u003e \u003cul style=\"margin: 0; padding-left: 18px; color: #444444;\"\u003e \u003cli\u003eSimultaneous testing of multiple detectors and sensor configurations\u003c\/li\u003e \u003cli\u003eTest bank supports up to three cylinder holders and 10 test stands—no messy calibration gas tubing\u003c\/li\u003e \u003cli\u003eGas cylinders can be RFID-enabled or manually configured\u003c\/li\u003e \u003cli\u003eCylinder Holder LEDs provide light band indication of low, empty, or expired calibration gas\u003c\/li\u003e \u003cli\u003eNo networking required for compliance reporting to the cloud-based MSA Grid account\u003c\/li\u003e \u003cli\u003eBank display shows current status, cylinder expiration, and cylinder pressure (PSI or Bar)\u003c\/li\u003e \u003cli\u003eTest Stand LEDs and display indicate current test and test stand status\u003c\/li\u003e \u003cli\u003eLeverages ALTAIR io 4 connectivity for fast, correct setup with no complex user interface\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Test Modes --\u003e \u003cdiv style=\"padding: 0 26px 18px 26px;\"\u003e \u003cdiv style=\"background: #f3f3f3; border: 1px solid #ffffff; border-radius: 14px; padding: 16px;\"\u003e \u003cdiv style=\"font-size: 18px; font-weight: bold; margin: 0 0 10px 0; color: #444444;\"\u003eTest Modes\u003c\/div\u003e \u003cdiv style=\"display: flex; gap: 10px; flex-wrap: wrap;\"\u003e \u003cdiv style=\"flex: 1; min-width: 220px; background: #ffffff; border: 1px solid #f3f3f3; border-radius: 12px; padding: 12px;\"\u003e \u003cdiv style=\"font-weight: bold; margin-bottom: 6px; color: #444444;\"\u003eSmart Mode\u003c\/div\u003e \u003cdiv style=\"color: #888888;\"\u003eDock performs a bump test or calibration as required by Grid-configured gas detector settings without user intervention. Hands-off operation to help ensure compliance.\u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1; min-width: 220px; background: #ffffff; border: 1px solid #f3f3f3; border-radius: 12px; padding: 12px;\"\u003e \u003cdiv style=\"font-weight: bold; margin-bottom: 6px; color: #444444;\"\u003eBump Test Only\u003c\/div\u003e \u003cdiv style=\"color: #888888;\"\u003eDock always performs a bump test on the inserted device. A calibration is never performed in this mode.\u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1; min-width: 220px; background: #ffffff; border: 1px solid #f3f3f3; border-radius: 12px; padding: 12px;\"\u003e \u003cdiv style=\"font-weight: bold; margin-bottom: 6px; color: #444444;\"\u003eCalibration Only\u003c\/div\u003e \u003cdiv style=\"color: #888888;\"\u003eDock always performs a calibration on the inserted device. A bump test is never performed in this mode.\u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1; min-width: 220px; background: #ffffff; border: 1px solid #f3f3f3; border-radius: 12px; padding: 12px;\"\u003e \u003cdiv style=\"font-weight: bold; margin-bottom: 6px; color: #444444;\"\u003eBump Test + Cal on Fail\u003c\/div\u003e \u003cdiv style=\"color: #888888;\"\u003eDock performs a bump test first; if it fails, Dock proceeds to calibration. If calibration is due, Dock skips bump and calibrates.\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Specifications --\u003e \u003cdiv style=\"padding: 0 26px 18px 26px;\"\u003e \u003cdiv style=\"background: #ffffff; border-top: 1px solid #07fc0f; border-left: 1px solid #f3f3f3; border-right: 1px solid #f3f3f3; border-bottom: 1px solid #f3f3f3; border-radius: 14px; padding: 16px;\"\u003e \u003cdiv style=\"font-size: 18px; font-weight: bold; margin: 0 0 10px 0; color: #444444;\"\u003eSpecifications\u003c\/div\u003e \u003ctable style=\"width: 70%;\" border=\"1\" frame=\"hsides\" cellpadding=\"5\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eApplications\u003c\/td\u003e \u003ctd\u003eEmergency Response\u003cbr\u003eConfined Space\u003cbr\u003eTurnarounds \u0026amp; Plant Maintenance\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eApprovals \/ Standards\u003c\/td\u003e \u003ctd\u003eRoHS and REACH\u003cbr\u003eFCC and EU (RED) Radio compliance\u003cbr\u003eCE and UKCA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDisplay Type\u003c\/td\u003e \u003ctd\u003eMulti-Lingual Support: English (Additional languages will be supported in future)\u003cbr\u003eBacklight: Integrated backlight for low-light viewing and at a distance\u003cbr\u003eUser Interface: Large, intuitive, and easy-to-read\u003cbr\u003eDisplay Technology: 3.5 inch, 320*480 (RGB), viewing angle 85 degrees\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMarkets\u003c\/td\u003e \u003ctd\u003eConstruction\u003cbr\u003eGeneral Industry\u003cbr\u003eUtilities\u003cbr\u003eOil \u0026amp; Gas\u003cbr\u003eMining\u003cbr\u003eFire Service\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMounting\u003c\/td\u003e \u003ctd\u003eMountable using DIN EN 50 022 Rail 1m x 35mm x 7.5mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower Supply\u003c\/td\u003e \u003ctd\u003eInput voltage: 5V, 5A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSize\u003c\/td\u003e \u003ctd\u003eTest Stand Weight: 1.14kg (2.52 lbs)\u003cbr\u003eTest Stand Dimensions: 15.5cm L x 16.4cm W x 30.3cm H (6.1” L x 6.5” W x 11.9” H)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDurability\u003c\/td\u003e \u003ctd\u003eOperating Temperature: 0C-40C (32F-104F)\u003cbr\u003eRugged Design: No doors or closures\u003cbr\u003eTest Stand tested to over 150,000 device insertions\u003cbr\u003eLatching mechanism withstands 75lb retention force\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eConnectivity \/ Wireless Interfaces\u003c\/td\u003e \u003ctd\u003eNo connectivity required to report Bank status to cloud including cylinder gas expiration, cylinder gas pressure, and test results\u003cbr\u003eBluetooth version 4.0\u003cbr\u003eIEEE 802.11 b\/g\/n WLAN interface for future features\u003cbr\u003eEthernet connectivity\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBump Test \u0026amp; Calibration\u003c\/td\u003e \u003ctd\u003eLow 0.25l\/min nominal flow rate\u003cbr\u003eIntegrated gas delivery system\u003cbr\u003eStandard Bump Test Time: max. 40 seconds\u003cbr\u003eStandard Calibration Time: approx. 150 seconds\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- How it Works --\u003e \u003cdiv style=\"padding: 0 26px 18px 26px;\"\u003e \u003cdiv style=\"background: #f3f3f3; border: 1px solid #ffffff; border-radius: 14px; padding: 16px;\"\u003e \u003cdiv style=\"font-size: 18px; font-weight: bold; margin: 0 0 10px 0; color: #444444;\"\u003eHow the ALTAIR io™ Dock Helps Your Team\u003c\/div\u003e \u003cdiv style=\"display: flex; gap: 10px; flex-wrap: wrap;\"\u003e \u003cdiv style=\"flex: 1; min-width: 240px; background: #ffffff; border: 1px solid #f3f3f3; border-radius: 12px; padding: 12px;\"\u003e \u003cdiv style=\"font-weight: bold; margin-bottom: 6px; color: #444444;\"\u003eReduce manual steps\u003c\/div\u003e \u003cdiv style=\"color: #888888;\"\u003eThe Dock recognizes when your ALTAIR io 4 needs a bump test and runs the appropriate test immediately while seated in the Dock.\u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1; min-width: 240px; background: #ffffff; border: 1px solid #f3f3f3; border-radius: 12px; padding: 12px;\"\u003e \u003cdiv style=\"font-weight: bold; margin-bottom: 6px; color: #444444;\"\u003eImprove compliance visibility\u003c\/div\u003e \u003cdiv style=\"color: #888888;\"\u003eCompliance reporting is sent immediately to your MSA Grid account to help reduce risk from manual logs or file management.\u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1; min-width: 240px; background: #ffffff; border: 1px solid #f3f3f3; border-radius: 12px; padding: 12px;\"\u003e \u003cdiv style=\"font-weight: bold; margin-bottom: 6px; color: #444444;\"\u003eScale your fleet\u003c\/div\u003e \u003cdiv style=\"color: #888888;\"\u003eTest banks support multiple detectors and sensor configurations, with flexible cylinder holder and test stand capacity.\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Ideal For --\u003e \u003cdiv style=\"padding: 0 26px 18px 26px;\"\u003e \u003cdiv style=\"background: #ffffff; border-top: 1px solid #07fc0f; border-left: 1px solid #f3f3f3; border-right: 1px solid #f3f3f3; border-bottom: 1px solid #f3f3f3; border-radius: 14px; padding: 16px;\"\u003e \u003cdiv style=\"font-size: 18px; font-weight: bold; margin: 0 0 10px 0; color: #444444;\"\u003eIdeal For\u003c\/div\u003e \u003cul style=\"margin: 0; padding-left: 18px; color: #444444;\"\u003e \u003cli\u003eSafety managers standardizing bump test and calibration workflows\u003c\/li\u003e \u003cli\u003eTeams supporting confined space entry and industrial maintenance programs\u003c\/li\u003e \u003cli\u003eEmergency response groups that need fast, repeatable testing and reporting\u003c\/li\u003e \u003cli\u003eOrganizations minimizing compliance risk from paper logs and manual record keeping\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Note --\u003e \u003cdiv style=\"padding: 0 26px 22px 26px;\"\u003e \u003cdiv style=\"background: #f3f3f3; border: 1px solid #ffffff; border-radius: 14px; padding: 14px;\"\u003e \u003cdiv style=\"font-weight: bold; margin-bottom: 6px; color: #444444;\"\u003eNote\u003c\/div\u003e \u003cdiv style=\"color: #888888;\"\u003eAlways read and follow product instructions and associated warnings\/cautions before use.\u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"color: #888888; font-size: 13px; margin-top: 10px;\"\u003eKeywords: ALTAIR io Dock, ALTAIR io 4 dock, MSA bump test station, MSA calibration dock, MSA Grid compliance reporting, multi-detector test bank.\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"MSA","offers":[{"title":"Default Title","offer_id":45783959896237,"sku":"285CS-10253973","price":2099.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/0766\/0205\/files\/io6_dock_nobg__61097.png?v=1773794406","url":"https:\/\/www.jendcosafety.com\/products\/msa-altair-io-dock-for-altair-io-6-10253973","provider":"Jendco Safety Supply","version":"1.0","type":"link"}