{"product_id":"omniguard-6-differential-pressure-recorder-cellular-modem-manometer-og6","title":"OmniGuard 6 Differential Pressure Recorder Cellular Modem Manometer - OG6","description":"\u003ch2 style=\"text-align: center;\"\u003eOmniGuard 6 Differential Pressure Recorder Cellular Modem Manometer - OG6\u003c\/h2\u003e\n\n\u003cp class=\"kicker\" style=\"text-align: center;\"\u003e\u003cstrong\u003eIncludes 2 Years of Verizon Wireless Service plus improved WiFi connectivity for reliable remote monitoring.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch3\u003ePurpose-Built for Containment Monitoring and Documentation\u003c\/h3\u003e\n\n\u003cp\u003e\u003cimg class=\"floatleft\" style=\"float: right;\" src=\"http:\/\/www.engsolinc.com\/graphics\/og\/og5openrt.jpg\" alt=\"Omniguard 4 Open\" width=\"290\" height=\"364\" border=\"0\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe OmniGuard 6 is designed to monitor and document vacuum and pressure inside containment areas. It is commonly used for asbestos, lead, and mold abatement monitoring and for clean room monitoring.\u003c\/p\u003e\n\n\u003cp\u003eThe self-contained design keeps essential components protected inside the case so the unit can operate with the lid closed. Dual inlet ports allow monitoring between two areas, supporting real-time differential pressure and\/or vacuum tracking.\u003c\/p\u003e\n\n\u003ch3\u003eWhat’s New in OmniGuard 6\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eUpgraded enterprise WiFi compatibility for robust connectivity in hospitals and other large institutions\u003c\/li\u003e\n\n\u003cli\u003eNew, more durable printer with easy-load paper replacement\u003c\/li\u003e\n\n\u003cli\u003eUpgraded cellular modem for increased power, reliability, and longevity\u003c\/li\u003e\n\n\u003cli\u003eExpanded log storage (4 MB) designed to hold 6+ months of normal job logs\u003c\/li\u003e\n\n\u003cli\u003eBuilt-in lithium ion battery supports portable operation up to 6 hours without AC power\u003c\/li\u003e\n\n\u003cli\u003eInternational power supply operation (80–240 VAC, 50–60 Hz)\u003c\/li\u003e\n\n\u003cli\u003eMultilingual interface options: English, French, and Spanish\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eCellular and WiFi Connectivity for Remote Updates\u003c\/h3\u003e\n\n\u003cp\u003eThe internal cellular modem helps you stay on top of projects when you are away from the job site. Receive status updates such as power changes, waiting for pressure, alarm conditions, or normal operation.\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eEnter up to four email addresses to receive status updates, job logs, or both\u003c\/li\u003e\n\n\u003cli\u003eEmail job log once per day at a selected time\u003c\/li\u003e\n\n\u003cli\u003eWiFi supports 802.11 b\/g\/n with WEP, WPA, or WPA2\u003c\/li\u003e\n\n\u003cli\u003eWiFi and cellular can email status changes up to four times per hour and send the last 24 hours job log once a day\u003c\/li\u003e\n\n\u003cli\u003eFirst two years of cellular service are included with purchase (Verizon coverage required in the USA)\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cdiv class=\"cta\"\u003e\n\u003cstrong\u003eOmniGuard Mobile App\u003c\/strong\u003e\n\n\u003cp class=\"subtle\"\u003eMobile app support for iOS and Android enables easy remote monitoring and notifications of multiple devices in one place.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003ch3\u003eOn-Site Documentation and Easy Log Retrieval\u003c\/h3\u003e\n\n\u003cp\u003eOmniGuard 6 includes an integrated thermal printer for physical logs and on-site documentation without ink ribbons. Log collection is supported by dual USB ports, allowing PC communication and direct export to a flash drive.\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eUSB Type-A port: save logs directly to a flash drive\u003c\/li\u003e\n\n\u003cli\u003eSecond USB port: PC communication for transferring logs, real-time monitoring, and configuration editing\u003c\/li\u003e\n\n\u003cli\u003eView logs on screen and scroll through memory contents\u003c\/li\u003e\n\n\u003cli\u003eAdjustable print\/log intervals to conserve paper and memory\u003c\/li\u003e\n\n\u003cli\u003eAutomatic printout and logging of all settings changes\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eClear Alarms, Wind-Stabilized Performance, and Tamper Protection\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eProgrammable high and low alarm setpoints\u003c\/li\u003e\n\n\u003cli\u003e95 dB audible alarm plus on-screen alarm indication\u003c\/li\u003e\n\n\u003cli\u003eVariable response rate to reduce nuisance alarms in windy environments\u003c\/li\u003e\n\n\u003cli\u003ePasscode protection and setting audit trail to help prevent tampering\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background: #f5f7fa; padding: 18px; border-left: 6px solid #003a8f; margin-bottom: 20px;\"\u003e\n\n\u003ch4\u003e\u003cspan style=\"color: #000080;\"\u003eBuilt In Cellular Modem\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cp\u003e\u003cimg class=\"__mce_add_custom__\" style=\"border: 1px solid black; float: right;\" src=\"http:\/\/www.engsolinc.com\/graphics\/og\/og5amail.jpg\" alt=\"Email\" width=\"248\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe internal cell modem lets you keep on top of your projects even when you're away from the job site. Get status updates when your Omniguard is turned on, when it starts monitoring and if it goes into an alarm.\u003c\/p\u003e\n\n\u003cp\u003eOnce a day, you can get an email with the job log for the last 24 hours for you to review and keep for your records. Two years of service are include \u003cstrong\u003e\u003ca href=\"https:\/\/www.engsolinc.com\/ogregister.php\"\u003efree when you register\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch4\u003e\u003cspan style=\"color: #000080;\"\u003eIncreased Battery Power\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cp style=\"text-align: right;\"\u003e\u003cimg class=\"__mce_add_custom__\" style=\"float: right; margin: 6px; border: 1px solid black;\" src=\"http:\/\/www.engsolinc.com\/graphics\/og\/og5battery.jpg\" alt=\"Battery\" width=\"248\" height=\"141\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eWith the addition of a built in lithium ion battery the Omniguard can now operate for up to 6 hours with out AC power. Even if you are working in an environment with potential power interruptions, you can be confident that your continuous job log will not be interrupted by a short loss of power.\u003c\/p\u003e\n\n\u003cp\u003ePower saving features such as auto shut off of the printer tape and a reduction in screen brightness allow the Omniguard to continue to monitor, and then will auto reset once power is available. The Omniguard makes it easy to monitor the battery life by indicating a power level percentage whenever the Omniguard is running off battery power.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg class=\"__mce_add_custom__\" style=\"float: right;\" src=\"http:\/\/www.engsolinc.com\/graphics\/og\/og5flashdrive.jpg\" alt=\"Flash Drive\" width=\"248\"\u003e\u003c\/p\u003e\n\n\u003ch4\u003e\u003cspan style=\"color: #000080;\"\u003eUSB Flash Drive Compatible\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cp\u003eSave logs directly to a USB flash drive on the job site. No need to carry a laptop with you or bring your Omniguards into the office just to retrieve the logs.\u003c\/p\u003e\n\n\u003cp\u003eYou can view and store the log files on your PC later using our free software.\u003c\/p\u003e\n\n\u003ch4\u003e\u003cspan style=\"color: #000080;\"\u003eInternational Upgrades\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cp\u003eThe Omniguard is now multilingual. Both the Omniguard user interface and the Omniguard Communication Software are now available in French as well as English. We will also be releasing the update for the Spanish firmware soon.\u003c\/p\u003e\n\n\u003cp\u003eThe Omniguard is equipped to handle the different power needs for our overseas customers. Each Omniguard now comes with a standard 85-240VAC power supply. Modifications for our international Omniguard are no longer necessary, which means lower costs for our customers and quicker turnaround for our international orders.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003ctable style=\"width: 80%;\" border=\"1\" frame=\"hsides\" cellpadding=\"5\"\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eOperating Pressure Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e  \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003e+\/- 0.250 inches Water Column ( +\/- 6.35 mm WC, +\/- 62.5 Pascals)\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003e+\/- 0.003 inches Water Column or +\/- 1% of reading whichever is greater\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003e0.001 inches Water Column ( +\/- 0.05 mm WC, +\/- 0.5 Pascals)\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eBurst Pressure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003e3 psi (20 kPa) on either inlet nozzle\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003ePressure Units\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003e\"WC (inches Water Column), mmWC (millimeters Water Column) or Pa (Pascals)\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eData (Log) Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003e4 MB non-volatile memory\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003e4.3\" Color Touchscreen LCD (480 x 272 pixels)\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eInternal Clock\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003eThe internal clock is powered by a self-charging lithium-ion battery that provides clock operation when AC power is not present\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003ePrinter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003e20 character wide thermal printer (uses 2.2\" wide thermal printer paper)\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003ePressure Reading Log Rates\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003eNormal Operation -- Highest and lowest pressure readings are logged \u0026amp; printed at intervals of 5, 15, 30 minutes or OFF\u003cbr\u003eAlarm Condition -- Highest and lowest pressure readings are logged \u0026amp; printed at intervals of 15, 30, 60 or 120 seconds for first 10 minutes of alarm condition, increasing to 15 minute intervals thereafter\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eAlarms\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003eTwo programmable alarm settings, 95db audible alarm and red bordered on-screen warning indicate alarm condition\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eCellular Service\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\n\u003cspan\u003eCellular modem can email status changes up to four times per hour and the jog log of the last 24 hours once a day. First two years are \u003c\/span\u003e\u003cstrong\u003efree\u003c\/strong\u003e\u003cspan\u003e. Service is provide by Verizon and is only available in areas with Verizon coverage in the USA.\u003c\/span\u003e\n\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eWiFi\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003e\u003cspan\u003eWiFi can email status changes up to four times per hour and the jog log of the last 24 hours once a day. Supports 802.11b\/g\/n with WEP, WPA or WPA2.\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003ePressure Inlet Nozzles\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003eTwo 3\/16\" OD barbed hose connectors, 10 ft of pressure hose provided\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eUSB Port\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003eUSB V1.1 Type-A\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eUSB Port\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003eUSB V1.1 Type-B\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eAC Power\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003e80-240 VAC 50-60Hz 10W (with 6 ft power cord)\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eBattery Power\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003eInternal rechargeable 3.7 Volt Li-ion type battery provides 4-6 hours of portable operation\u003cbr\u003eRecharges in 4 hours when AC power is available (printer is disabled when powered by battery)\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eCase\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003eDimensions 9.25\" x 7.5\" x 4.5\" \/ Shipping Weight 8 lbs\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003cspan class=\"fieldname\"\u003eWarranty\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"text-align: right;\"\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan class=\"std\"\u003eOne Year Limited Warranty\u003c\/span\u003e\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003ch4 class=\"catchphrase\" align=\"center\"\u003e\u003cstrong\u003eRugged. Accurate. Easy.\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cp\u003e\u003cimg src=\"http:\/\/www.engsolinc.com\/graphics\/og\/og5inside.jpg\" alt=\"Omniguard 4 Open\" width=\"270\" height=\"221\" align=\"left\" border=\"1\" hspace=\"12\" vspace=\"6\"\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEasy To Use\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe Omniguard is a differential pressure recorder in a completely self-contained package, designed from the beginning to be extremely versatile yet easy to use. The included accessories, owner's manual, hose, a spare roll of paper and AC cord, store easily in the lid. There's no AC adapter to keep track of.\u003c\/p\u003e\n\n\u003cp\u003eIt's easy to find a convenient spot to place the unit since the Omniguard is not position sensitive and can be hung by a nail using the built in hanger. Accurate measurements continue even if the unit is repositioned or moved. The 4.3\" color graphics display provides the easiest setup possible. Pressure is indicated with large easy to read characters and alarm setpoints are always displayed. Screen icons show the monitoring, printer and audible alarm status with a glance. Detailed information for job setup, feature settings and operating instructions, and troubleshooting tips are available on-screen at any time by accessing the Help menu. Pressure readings are time stamped and logged into memory once containment has been established. Audible and visual alarms activate whenever the pressure reaches the alarm setpoints.\u003c\/p\u003e\n\n\u003cp\u003eThe Omniguard ensures the site inspector that proper containment was maintained. Logs and summary reports can be printed at any time for easy inspection of the monitoring data. Durable and reliable, the Omniguard is clearly the contractors choice for containment monitoring.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp align=\"center\"\u003e\u003cstrong\u003eEasily navigate the menus and settings using the user-friendly touch screen interface.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe intuitive lay out and menu orientations mean you can quickly and easily set up and start a job. Touch the icons on the home page to adjust their correlating set points, and use the alpha numeric key board to personalize the contractor and job names and password protection settings.\u003c\/p\u003e\n\n\u003cp align=\"center\"\u003e\u003cem\u003eMultiple screens allow the user to easily inspect and adjust the settings for specific job requirements.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; margin-left: auto; margin-right: auto; height: 417px;\" border=\"0\" cellspacing=\"6\" cellpadding=\"6\"\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd valign=\"top\"\u003e\n\u003ccenter\u003e\n\u003cimg src=\"http:\/\/www.engsolinc.com\/graphics\/og\/og5home.jpg\" alt=\"Home Screen\" align=\"center\" hspace=\"2\" vspace=\"2\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eHome Screen\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003c\/center\u003e\n\n\u003cp\u003eView current pressure reading and alarm settings. Monitoring status is shown at the screen bottom. Printer and Alarm status are indicated by on-screen icons. The color-coded border represents the different alarm conditions.\u003c\/p\u003e\n\n\u003c\/td\u003e\n\n\u003ctd valign=\"top\" width=\"50%\"\u003e\n\u003ccenter\u003e\n\u003cimg src=\"http:\/\/www.engsolinc.com\/graphics\/og\/og5menu.jpg\" alt=\"Main Menu\" align=\"center\" hspace=\"2\" vspace=\"2\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eMain Menu\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003c\/center\u003e\n\n\u003cp\u003eScroll through a menu of all the editable functions and settings. Start or end a job and access the tutorial.\u003c\/p\u003e\n\n\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd valign=\"top\"\u003e\n\u003ccenter\u003e\n\u003cimg src=\"http:\/\/www.engsolinc.com\/graphics\/og\/og5alarm.jpg\" alt=\"Alarm Settings Screen\" align=\"center\" hspace=\"2\" vspace=\"2\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eAlarm Settings Screen\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003c\/center\u003e\n\n\u003cp\u003eMake changes to configurable alarm set points, response rate and unit of measure. Saved settings are logged into memory and printed to the report.\u003c\/p\u003e\n\n\u003c\/td\u003e\n\n\u003ctd valign=\"top\"\u003e\n\u003ccenter\u003e\n\u003cimg src=\"http:\/\/www.engsolinc.com\/graphics\/og\/og5print.jpg\" alt=\"Print\/Report Screen\" align=\"center\" hspace=\"2\" vspace=\"2\"\u003e\n\n\u003cp\u003e\u003cstrong\u003ePrinting and Reports\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003c\/center\u003e\n\n\u003cp\u003eFind, view and print reports with ease from the printer\/reports screen. Quickly turn the printer on or off, and view a report on the screen prior to printing. Simply scroll through any of the saved job logs on the Omniguard and choose the duration of the report you would like to print, ie: Today's job log, the last 24hr, 48 hrs, 72 hrs or the whole report.\u003c\/p\u003e\n\n\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd valign=\"top\" width=\"50%\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eEasy To Read\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe Omniguard comes equipped with a thermal printer that provides a detailed, easy to read log of the pressure in the containment area as well as recording any changes made to the setup. Retrieving the data log is now quick and easy and more comprehensive than ever before. Touch the printer icon to bring you to the Printer Settings Menu, choose from any job log stored on the Omniguard, then choose to print the log from today, the last 24\/48\/72 hours, or the entire log. You now also have the option to view the log directly on the screen, rather than printing the entire log.\u003c\/p\u003e\n\n\u003cp\u003eEach of these reports offers the user specific, pertinent information and a hard copy record of the data logged from the containment area.\u003c\/p\u003e\n\n\u003cp\u003eEach printout provides a summary of the current job status, including the amount of time in Normal Operation, the number of Alarms and the amount time in Alarm Conditions (if any) along with an area for sign-off. In addition, a Configuration Report can be viewed and printed from the Printer Settings Menu. The Configuration Report provides a hard copy of all of operational settings, memory usage and log space available.\u003c\/p\u003e\n\n\u003c\/td\u003e\n\n\u003ctd align=\"center\" valign=\"top\"\u003e\n\u003cimg src=\"http:\/\/www.engsolinc.com\/graphics\/og\/printout.png\" alt=\"Job Report\" width=\"452\" height=\"619\" hspace=\"4\"\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\n\u003c\/table\u003e","brand":"Engineering Solutions","offers":[{"title":"Default Title","offer_id":45783954030765,"sku":"280-OMNIGUARD6","price":1899.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/0766\/0205\/files\/EngSolProduct-20__26806.jpg?v=1777527199","url":"https:\/\/www.jendcosafety.com\/products\/omniguard-6-differential-pressure-recorder-cellular-modem-manometer-og6","provider":"Jendco Safety Supply","version":"1.0","type":"link"}